4400-10-56 LaserSource, 10A/56V

At-a-Glance.

  • 10A / 56V range
  • Both CW and QCW operation
  • 0.5mA resolution
  • USB and RS-232 interfaces

$5,395.00

CONTACT FACTORY FOR LEAD TIME

The 4400-10-56 LaserSource provides up to 10A of current at up to 56V compliance, with excellent noise and accuracy specs. The 4400-10-56 is an excellent choice for applications that demand high compliance voltages, such as laser modules with many diodes in series. It supports both CW and Quasi-CW (QCW) mode.

Pilot Laser

In addition to the primary laser output, the 4400 includes control of a secondary pilot (or pointing) laser that is often integrated into high-power laser modules.

Simple User Interface

The user interface is remarkably simple… so easy to use, you’ll have it up and running in no time. Unlike other instruments which rely on 7-segment LED displays and a confusing array of indicators and buttons, the 4400 instead presents information on a high contrast VFD display in an easy-to-read format., and displays current, voltage, and photodiode current simultaneously… no need to toggle through the readings as you would on most instruments. Settings and error messages are in clear English, not cryptic codes and flashing status lights.

Quasi-CW (QCW) Mode

The 4400 includes QCW mode, as many applications require the low duty cycle, high current pulses that QCW offers to manage thermal loading on the device.

Standard Computer Interfaces

The 4400 includes both USB and RS232 computer interfaces, allowing for quick and easy connection to a PC for remote operation. In addition, the LaserSource’s command set is compatible with ILX and Newport controllers, allowing you to leverage any existing software you may have already developed.

Ground Loops Eliminated

Like all LaserSources, the 4400 includes isolated inputs and outputs. In technical terms, this means that every input and output signal is electrically isolated, so that offset voltages, ground connections, and AC noise will not “bleed” into other parts of the electronics. Even the photodiode input is fully isolated from the laser output, ensuring full isolation of the laser output. In practical terms, this means it’s impossible to create a ground loop through the LaserSource, a common problem in laboratory setups where several different instruments are used in the same test. No other driver on the market has this capability.

Analog Modulation

The 4400 supports analog modulation via a front panel BNC for arbitrary control of the current output using an external function generator or voltage source.

4400-10-56 LaserSource FAQ

Arroyo Instruments temperature controllers feature bipolar current output, allowing for heating and cooling applications. All Arroyo Instruments temperature controllers, including the OEM packaged 585 and 586 Series TECPak controllers, provide heating and cooling capabilities.

Yes, Arroyo Instruments TEC controllers offer both low and high temperature set point limits, as well as the ability to fine-tune the controller’s PID parameters. PID parameters can be adjusted using eight standard factory gain settings that are numbered 1 through 300. Increasing the controller’s gain value will increase the speed of your control loop, while a rapid temperature fluctuation can be fixed by reducing the gain value. Users may need to experiment with a few different factory gain values to find the ideal value, and the gain can also be set to PID for even finer tuning. The PID parameters can also be set via the AutoTune Function, where the controller calculates ideal PID values based on your typical operating conditions. Please refer to your temperature controller’s user manual for more information and guidance for starting the Autotune feature.

Yes, most models support USB and RS-232 connections, with a select few models supporting Ethernet. Both the Arroyo benchtop and OEM temperature controllers can be controlled remotely via the ArroyoControl software, or integrated into custom systems using software such as LabVIEW, Python, and MATLAB.

The 585 and 586 Series TECPak temperature controllers are designed for compact, custom systems, and support PC-based control via USB and RS-232 communication interfaces. Both the 585 and 586 can be mounted in a standard 19 inch rack, and the 585 Series TECPak also includes an analog interface.

The TECPak Series controllers feature bipolar output capability like the rest of the Arroyo Instruments temperature controller selection. The 585 and 586 Series support NTC thermistors and 2 and 4-wire RTDs, while the 586 Series also supports LM335 sensors.

The Arroyo Instruments line of temperature controllers was designed for precision temperature control across a broad range of applications. Common applications and testing environments are laboratory/university research work, laser diode characterization, industrial and manufacturing testing applications, and OEM system integration.

Arroyo Instruments temperature controllers have a temperature stability specification of ±0.004°C over a 1 hour span and ±0.01°C over 24 hours at an ambient room temperature of roughly 25°C.

Other Products in this Series

ModelCurrentVoltageAccuracyNoiseBWQCW
4400-10-56 LaserSource, 10A/56V10 A56 V0.05% + 0.005 A< 5 mA40 kHzYes
4400-15-28 LaserSource, 15A/28V15 A28 V0.05% + 0.0075 A< 8 mA40 kHzYes
4400-30-28 LaserSource, 30A/28V30 A28 V0.05% + 0.015 A< 15 mA35 kHzYes
4400-40-24 LaserSource, 40A/24V40 A24 V0.05% + 0.02 A< 20 mA25 kHzYes
4400-60-14 LaserSource, 60A/14V60 A14 V0.05% + 0.03 A< 30 mA20 kHzYes
4400-80-12 LaserSource, 80A/12V80 A12 V0.05% + 0.04 A< 40 mA20 kHzYes
4400-20-48 LaserSource, 20A/48V20 A48 V0.05% + 0.01 A< 10 mA35 kHzYes
4400-100-10 LaserSource, 100A/10V100 A10 V0.05% + 0.05 A< 50 mA15 kHzYes